Quality System
Quality System & Standards
The standards, traceability and management arrangements that govern the work described on this site.
Overview
Calibration and performance verification are performed by laboratories accredited to ISO/IEC 17025:2017. Accreditation is held by the performing laboratory, under the scope published by its accreditation body. Requests are matched to a laboratory's published scope before a quote is issued, so the certificate returned actually covers the measurement, range and uncertainty the customer needs.

Standards Referenced
Work described on this site is performed under ISO/IEC 17025:2017.
Where accreditation appears on this site it refers to the performing laboratory's own accreditation, limited to the measurements in its published scope. Requests that fall outside that scope are accepted where the capability exists, reported as non-accredited, and identified as such on the certificate. Every accreditation named here belongs to the laboratory performing the measurement.
What is included with a quotation is explained on the accreditation documentation page.

Metrological Traceability
Measurements are traceable to the SI through NIST, documented as an unbroken chain of comparisons, each carrying a stated uncertainty. Certificates state the reference standards used, the measured results with units, the expanded uncertainty with its coverage factor, and the decision rule applied wherever a statement of conformity is given. Where adjustment or repair occurs, both as-found and as-left results are reported, so a customer can assess whether a prior inspection decision was affected by an out-of-tolerance condition.
Each measurement carries its own traceability record rather than a blanket statement: the certificate identifies the reference used, that reference's calibration status, and the documented chain linking it to the SI unit. If a reference is later found out of tolerance, everything measured against it since its last calibration is reviewed and the affected customers are told.
Equipment and Maintenance
Partner laboratories test bridge, gantry and cantilever coordinate measuring machines and portable articulated arms against the standard matched to that frame type, using granite surface plates, gauge blocks, and ring and plug gauges as reference artifacts. Accredited and non-accredited items are identified separately on the quote and on the certificate. Out-of-tolerance findings are reported with as-found data before any adjustment proceeds, supporting a reverse-traceability review where required.
References are uniquely identified, environmentally controlled, and recalibrated to a defined schedule that drift data can shorten but not quietly extend. Damaged, overloaded or questionable equipment is removed from service and labelled until it has been verified and formally released back into use.
Management System
The work sits inside a documented management system:
- 01
Controlled documents
Procedures carry issue and revision status.
- 02
Retained records
Retained for a defined period and retrievable against a certificate number.
- 03
Audit and review
Internal audit and management review run on a schedule.
- 04
Corrective action
Nonconforming work and improvement actions are tracked to closure, and their effectiveness is checked afterwards.
Impartiality and Complaints
Where impartiality could be compromised the risk is identified and controlled, and the reported result follows the measurement rather than the commercial interest. Complaints and appeals are a formal input to the system — the process, including the response commitment, is set out on the complaints policy page. How results should and should not be read is covered on the disclaimer page.

Working on an approved-vendor file?
Scope, method statements and traceability detail are supplied with the quotation.